<?xml version="1.0" encoding="iso-8859-1"?><!-- generator="b2evolution/2.4.7" -->
<rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:admin="http://webns.net/mvcb/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:content="http://purl.org/rss/1.0/modules/content/">
	<channel>
		<title>Doctor Nick - Latest comments</title>
		<link>http://kaijaks.co.uk/blog/nick?disp=comments</link>
		<description></description>
		<language>en-UK</language>
		<docs>http://backend.userland.com/rss</docs>
		<admin:generatorAgent rdf:resource="http://b2evolution.net/?v=2.4.7"/>
		<ttl>60</ttl>
				<item>
			<title>In response to: My favourite russian word</title>
			<pubDate>Thu, 19 Aug 2010 18:17:52 +0000</pubDate>
			<dc:creator>dr-nick [Member]</dc:creator>
			<guid isPermaLink="false">c586@http://kaijaks.co.uk/blog/</guid>
			<description>@Zarko, thanks for the correction :)</description>
			<content:encoded><![CDATA[@Zarko, thanks for the correction :)]]></content:encoded>
			<link>http://kaijaks.co.uk/blog/nick/2010/08/17/my-favourite-russian-word#c586</link>
		</item>
				<item>
			<title>In response to: My favourite russian word</title>
			<pubDate>Thu, 19 Aug 2010 03:45:18 +0000</pubDate>
			<dc:creator>Zarko [Visitor]</dc:creator>
			<guid isPermaLink="false">c583@http://kaijaks.co.uk/blog/</guid>
			<description>Actually Shapka is a word for Russian Berrete, an army cap, but later people started using it as a common term for a hat, which origially should be &quot;kapa&quot; :)</description>
			<content:encoded><![CDATA[Actually Shapka is a word for Russian Berrete, an army cap, but later people started using it as a common term for a hat, which origially should be "kapa" :)]]></content:encoded>
			<link>http://kaijaks.co.uk/blog/nick/2010/08/17/my-favourite-russian-word#c583</link>
		</item>
				<item>
			<title>In response to: ExpandPath() bug in ColdFusion 8</title>
			<pubDate>Tue, 17 Aug 2010 21:21:02 +0000</pubDate>
			<dc:creator>dr-nick [Member]</dc:creator>
			<guid isPermaLink="false">c582@http://kaijaks.co.uk/blog/</guid>
			<description>@David,&lt;br /&gt;
&lt;br /&gt;
Pleasure! I thought at the time - this isn't documented anywhere, and it's so bizarre it needed to be :)</description>
			<content:encoded><![CDATA[@David,<br />
<br />
Pleasure! I thought at the time - this isn't documented anywhere, and it's so bizarre it needed to be :)]]></content:encoded>
			<link>http://kaijaks.co.uk/blog/nick/2009/04/30/expandpath-bug-in-coldfusion-8#c582</link>
		</item>
				<item>
			<title>In response to: ExpandPath() bug in ColdFusion 8</title>
			<pubDate>Tue, 17 Aug 2010 20:48:51 +0000</pubDate>
			<dc:creator>David [Visitor]</dc:creator>
			<guid isPermaLink="false">c581@http://kaijaks.co.uk/blog/</guid>
			<description>THANK YOU!&lt;br /&gt;
you just eased lots of pain for us!</description>
			<content:encoded><![CDATA[THANK YOU!<br />
you just eased lots of pain for us!]]></content:encoded>
			<link>http://kaijaks.co.uk/blog/nick/2009/04/30/expandpath-bug-in-coldfusion-8#c581</link>
		</item>
				<item>
			<title>In response to: Dodgy old boiler</title>
			<pubDate>Mon, 26 Jul 2010 11:42:18 +0000</pubDate>
			<dc:creator>Simon Carus-Wilson [Visitor]</dc:creator>
			<guid isPermaLink="false">c559@http://kaijaks.co.uk/blog/</guid>
			<description>39p spent at Maplins and my Potterton Prima F 60 is purring like a kitten.&lt;br /&gt;
&lt;br /&gt;
Thank you so much.&lt;br /&gt;
&lt;br /&gt;
All the best Simon</description>
			<content:encoded><![CDATA[39p spent at Maplins and my Potterton Prima F 60 is purring like a kitten.<br />
<br />
Thank you so much.<br />
<br />
All the best Simon]]></content:encoded>
			<link>http://kaijaks.co.uk/blog/nick/2008/02/10/dodgy-old-boiler#c559</link>
		</item>
				<item>
			<title>In response to: Dodgy old boiler</title>
			<pubDate>Fri, 02 Jul 2010 20:28:13 +0000</pubDate>
			<dc:creator>dr-nick [Member]</dc:creator>
			<guid isPermaLink="false">c549@http://kaijaks.co.uk/blog/</guid>
			<description>@Kim, thanks for the tip, certainly agree on the design!</description>
			<content:encoded><![CDATA[@Kim, thanks for the tip, certainly agree on the design!]]></content:encoded>
			<link>http://kaijaks.co.uk/blog/nick/2008/02/10/dodgy-old-boiler#c549</link>
		</item>
				<item>
			<title>In response to: Dodgy old boiler</title>
			<pubDate>Fri, 02 Jul 2010 18:48:18 +0000</pubDate>
			<dc:creator>Kim [Visitor]</dc:creator>
			<guid isPermaLink="false">c548@http://kaijaks.co.uk/blog/</guid>
			<description>Hi,  Ref Prima 60F &lt;br /&gt;
just another note that might help somebody else. &lt;br /&gt;
Reading through the comments,  somebody asked the question (could the caps be at fault on a 15 month old pcb)  Well the answer is yes and the last thing I expected.  Mine was about 16 months old and looked like new inside. No sign of the usual bad joints at the base of the plug socket etc.  I replaced all 3 caps, but the faulty one was the axial one (wires come out at either end) C7  22uF.  Maplin p/n AT04E They don't do this in 100v or 103 degC versions so 63V had to do.  Anyway when tested, the faulty one measured 4uF rather than 22uF &lt;br /&gt;
&lt;br /&gt;
The problem with the boiler was:  On fire up, it would run the fan for 5 sec then stop then run 5 sec again between 4 or 10 times before firing.  It would never try to spark.  Basically I guess it needs a few seconds more than 5 to allow enough diff pressure to pull the Air Press SW in&lt;br /&gt;
&lt;br /&gt;
I carried out the flame safety test procedures shown in the manual after reinstalling the pcb and I would recommend this to others.  &lt;br /&gt;
&lt;br /&gt;
Given the application and location of the pcb,  I have never seen such poor build quality. It is basically designed to fail after a couple of years max.   &lt;br /&gt;
&lt;br /&gt;
Regards  Kim</description>
			<content:encoded><![CDATA[Hi,  Ref Prima 60F <br />
just another note that might help somebody else. <br />
Reading through the comments,  somebody asked the question (could the caps be at fault on a 15 month old pcb)  Well the answer is yes and the last thing I expected.  Mine was about 16 months old and looked like new inside. No sign of the usual bad joints at the base of the plug socket etc.  I replaced all 3 caps, but the faulty one was the axial one (wires come out at either end) C7  22uF.  Maplin p/n AT04E They don't do this in 100v or 103 degC versions so 63V had to do.  Anyway when tested, the faulty one measured 4uF rather than 22uF <br />
<br />
The problem with the boiler was:  On fire up, it would run the fan for 5 sec then stop then run 5 sec again between 4 or 10 times before firing.  It would never try to spark.  Basically I guess it needs a few seconds more than 5 to allow enough diff pressure to pull the Air Press SW in<br />
<br />
I carried out the flame safety test procedures shown in the manual after reinstalling the pcb and I would recommend this to others.  <br />
<br />
Given the application and location of the pcb,  I have never seen such poor build quality. It is basically designed to fail after a couple of years max.   <br />
<br />
Regards  Kim]]></content:encoded>
			<link>http://kaijaks.co.uk/blog/nick/2008/02/10/dodgy-old-boiler#c548</link>
		</item>
				<item>
			<title>In response to: Dodgy old boiler</title>
			<pubDate>Thu, 10 Jun 2010 01:01:00 +0000</pubDate>
			<dc:creator>Stan [Visitor]</dc:creator>
			<guid isPermaLink="false">c543@http://kaijaks.co.uk/blog/</guid>
			<description>Found your page via google when I returned home to find that there was no hot water and the Profile 80e wouldn't fire up.&lt;br /&gt;
&lt;br /&gt;
Noticed some arcing and sparking from underneath the front right hand side of the PCB, whipped it out and found a nasty cracked dry joint. &lt;br /&gt;
&lt;br /&gt;
Fired up the soldering iron and 5 minutes later the boiler was back working and the water was heating.&lt;br /&gt;
&lt;br /&gt;
Thanks for your informative write up, if I do need to change the capactitors do need replacing in the future, I am well up to speed on getting the PCB out for another quick repair.</description>
			<content:encoded><![CDATA[Found your page via google when I returned home to find that there was no hot water and the Profile 80e wouldn't fire up.<br />
<br />
Noticed some arcing and sparking from underneath the front right hand side of the PCB, whipped it out and found a nasty cracked dry joint. <br />
<br />
Fired up the soldering iron and 5 minutes later the boiler was back working and the water was heating.<br />
<br />
Thanks for your informative write up, if I do need to change the capactitors do need replacing in the future, I am well up to speed on getting the PCB out for another quick repair.]]></content:encoded>
			<link>http://kaijaks.co.uk/blog/nick/2008/02/10/dodgy-old-boiler#c543</link>
		</item>